Search filters

List of works by Pejman Rowshanfarzad

A cine-EPID based method for jaw detection and quality assurance for tracking jaw in IMRT/VMAT treatments.

scientific article published on 28 November 2014

A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems

scientific article

A comprehensive study of the mechanical performance of gantry, EPID and the MLC assembly in Elekta linacs during gantry rotation.

scientific article published on 23 April 2015

An EPID-based method for comprehensive verification of gantry, EPID and the MLC carriage positional accuracy in Varian linacs during arc treatments.

scientific article published on 26 November 2014

An independent system for real-time dynamic multileaf collimation trajectory verification using EPID.

scientific article published on 12 December 2013

An investigation of gantry angle data accuracy for cine-mode EPID images acquired during arc IMRT.

scientific article

Beam focal spot intrafraction motion and gantry angle dependence: A study of Varian linac focal spot alignment

scientific article published on 29 May 2019

Commissioning and performance characteristics of a pre-clinical image-guided radiotherapy system.

scientific article

Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging.

scientific article published in February 2012

Detection of the focal spot motion relative to the collimator axis of a linear accelerator under gantry rotation

scientific article published on 31 January 2019

EPID‐based verification of the MLC performance for dynamic IMRT and VMAT

scientific article published on October 1, 2012

Evaluation of a mobile C-arm cone-beam CT in interstitial high-dose-rate prostate brachytherapy treatment planning.

scientific article published on 3 April 2019

Evaluation of the Impact of the Linac MLC and Gantry Sag in volumetric modulated arc therapy

scientific article published on 01 April 2019

Gantry angle determination during arc IMRT: evaluation of a simple EPID-based technique and two commercial inclinometers.

scientific article published on 8 November 2012

Gantry-angle resolved VMAT pretreatment verification using EPID image prediction.

scientific article published in August 2013

Impact of backscattered radiation from the bunker structure on EPID dosimetry.

scientific article published on 8 November 2012

Improvement of Varian a-Si EPID dosimetry measurements using a lead-shielded support-arm.

scientific article published on 16 September 2011

Investigation of the accuracy of MV radiation isocentre calculations in the Elekta cone-beam CT software XVI.

scientific article

Investigation of the mechanical performance of Siemens linacs components during arc: gantry, MLC, and electronic portal imaging device

scientific article published on 5 November 2015

Investigation of the sag in linac secondary collimator and MLC carriage during arc deliveries.

scientific article published on 30 May 2012

Isocenter verification for linac-based stereotactic radiation therapy: review of principles and techniques.

scientific article

MLC positioning verification for small fields: a new investigation into automatic EPID-based verification methods

scientific article published on 27 September 2018

Preclinical studies of [61Cu]ATSM as a PET radiopharmaceutical for fibrosarcoma imaging.

scientific article

Radiomics for Identification and Prediction in Metastatic Prostate Cancer: A Review of Studies

publication published on 01 November 2021

Reduction of the effect of non-uniform backscatter from an E-type support arm of a Varian a-Si EPID used for dosimetry.

scientific article published on 20 October 2010

Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration.

scientific article published on 17 July 2012

Transit dosimetry in dynamic IMRT with an a-Si EPID.

scientific article published on 31 May 2014

VMAT linear accelerator commissioning and quality assurance: dose control and gantry speed tests

scientific article published on 8 May 2016

Verification of the linac isocenter for stereotactic radiosurgery using cine‐EPID imaging and arc delivery

scientific article published on July 1, 2011