Search filters

List of works by Luc Beaulieu

3D heterogeneous dose distributions for total body irradiation patients

scientific article published in June 2011

3D heterogeneous dose distributions for total body irradiation patients.

scientific article

3D source tracking and error detection in HDR using two independent scintillator dosimetry systems

scientific article published on 22 November 2020

3D tomodosimetry using long scintillating fibers: a feasibility study

scientific article published in October 2013

A GPU-based multi-criteria optimization algorithm for HDR brachytherapy

scientific article published on 08 May 2019

A Monte Carlo study on the effect of seed design on the interseed attenuation in permanent prostate implants

scientific article published in August 2008

A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife

scientific article published on 01 January 2013

A design methodology using signal-to-noise ratio for plastic scintillation detectors design and performance optimization

scientific article

A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate 192 Ir brachytherapy.

scientific article

A generic high-dose rate (192)Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

scientific article

A mathematical formalism for hyperspectral, multipoint plastic scintillation detectors.

scientific article published on 12 October 2012

A maximum likelihood method for high resolution proton radiography/proton CT.

scientific article published on 3 November 2016

A more efficient, radiation-free alternative to systematic chest x-ray for the detection of embolized seeds to the lung

scientific article published on 06 March 2010

A multi-criteria optimization approach for HDR prostate brachytherapy: I. Pareto surface approximation

scientific article published on 16 October 2018

A multi-criteria optimization approach for HDR prostate brachytherapy: II. Benchmark against clinical plans

scientific article published on 16 October 2018

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

scientific article published on 01 December 2011

A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy

scientific article

A simplified analytical dose calculation algorithm accounting for tissue heterogeneity for low-energy brachytherapy sources

scientific article published on 22 August 2013

A stochastic frontier analysis for enhanced treatment quality of high-dose-rate brachytherapy plans

scientific article published on 14 March 2019

A systematic characterization of the low-energy photon response of plastic scintillation detectors.

scientific article published on 6 July 2016

A theoretical framework to predict the most likely ion path in particle imaging

scientific article published on 11 January 2017

AAPM and GEC-ESTRO guidelines for image-guided robotic brachytherapy: report of Task Group 192.

scientific article published on October 2014

ALGEBRA: ALgorithm for the heterogeneous dosimetry based on GEANT4 for BRAchytherapy.

scientific article published on 9 May 2012

Accurate calibration of a polymer gel dosimeter with a plastic scintillation detector.

scientific article

Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

scientific article published in November 2013

Advances in Radiotherapy for Prostate Cancer Treatment

scientific article

An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: experimental and clinical studies

scientific article published in July 2005

An algorithm for efficient metal artifact reductions in permanent seed

scientific article published in January 2011

An eight-year experience of HDR brachytherapy boost for localized prostate cancer: biopsy and PSA outcome.

scientific article

An opposite view data replacement approach for reducing artifacts due to metallic dental objects.

scientific article

Anatomy-based inverse planning dose optimization in HDR prostate implant: a toxicity study.

scientific article published in June 2005

Attenuator design for organs at risk in total body irradiation using a translation technique.

scientific article

Automated seed detection and three-dimensional reconstruction. I. Seed localization from fluoroscopic images or radiographs

scientific article published in November 2001

Automated seed detection and three-dimensional reconstruction. II. Reconstruction of permanent prostate implants using simulated annealing

scientific article published in November 2001

Automatic generation of anatomy-based MLC fields in aperture-based IMRT.

scientific article published in June 2004

Automatic post-implant needle reconstruction algorithm to characterize and improve implant robustness analyses

scientific article published in November 2003

Benchmarking a novel inorganic scintillation detector for applications in radiation therapy

scientific article published on 26 November 2019

Brachytherapy Future Directions

scientific article published on 01 January 2020

Bypassing the learning curve in permanent seed implants using state-of-the-art technology

scientific article published on 25 September 2006

COMP report: CPQR technical quality control guidelines for low-dose-rate permanent seed brachytherapy.

scientific article

Calcifications in low-dose rate prostate seed brachytherapy treatment: post-planning dosimetry and predictive factors.

scientific article published on 20 February 2015

Characterization of a binary system composed of luminescent quantum dots for liquid scintillation

scientific article published on 06 September 2018

Characterization of a plastic scintillating detector for the Small Animal Radiation Research Platform (SARRP)

scientific article published on 13 December 2018

Characterizing the response of miniature scintillation detectors when irradiated with proton beams.

scientific article published on 10 March 2008

Clinical outcome of adjuvant treatment of endometrial cancer using aperture-based intensity-modulated radiotherapy

scientific article published on 04 March 2008

Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications

scientific article published in August 2008

Comment on 'Plastic scintillation dosimetry: comparison of three solutions for the Cerenkov challenge'.

scientific article published in June 2012

Commissioning and evaluation of an extended SSD photon model for PINNACLE3: an application to total body irradiation

scientific article published in August 2009

Comparison of TG-43 and TG-186 in breast irradiation using a low energy electronic brachytherapy source.

scientific article

Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy

scientific article published on 7 November 2015

Consequences of dose heterogeneity on the biological efficiency of ¹⁰³Pd permanent breast seed implants

scientific article published on 18 January 2012

Correction of CT artifacts and its influence on Monte Carlo dose calculations

scientific article published in June 2007

Correction of megavoltage cone-beam CT images for dose calculation in the head and neck region

scientific article

Correction of megavoltage cone-beam CT images of the pelvic region based on phantom measurements for dose calculation purposes

scientific article published on 27 January 2009

Coupling I-125 permanent implant prostate brachytherapy Monte Carlo dose calculations with radiobiological models

scientific article published on 12 July 2017

Dependence of intermediate mass fragment production on the reaction mechanism in light heavy-ion collisions at intermediate energy

scientific article published on 01 February 1996

Developing a phenomenological model of the proton trajectory within a heterogeneous medium required for proton imaging

scientific article published on 10 June 2015

Development of a novel multi-point plastic scintillation detector with a single optical transmission line for radiation dose measurement.

scientific article published on 12 October 2012

Development of a reverse enzymoallergosorbent test (REAST) to detect timothy-specific IgE antibodies. Comparison with RAST

scientific article published on 01 January 1986

Development of virtual patient models for permanent implant brachytherapy Monte Carlo dose calculations: interdependence of CT image artifact mitigation and tissue assignment.

scientific article published on 28 July 2015

Dietary protein hydrolysate and trypsin inhibitor effects on digestive capacities and performances during early-stages of spotted wolffish: Suggested mechanisms

scientific article published on 08 January 2011

Direct Measurement of Dissipation in the 35Cl+12C Reaction at 43 MeV/nucleon

scientific article published on 01 July 1996

Does Seed Migration Increase the Risk of Second Malignancies in Prostate Cancer Patients Treated With Iodine-125 Loose Seeds Brachytherapy?

scientific article published on 28 December 2017

Does prostate volume has an impact on biochemical failure in patients with localized prostate cancer treated with HDR boost?

scientific article published on 21 October 2016

Dose escalation in the radiotherapy of non-small-cell lung cancer with aperture-based intensity modulation and photon beam energy optimization for non-preselected patients

scientific article published on 08 January 2009

Dose escalation to the dominant intraprostatic lesion defined by sextant biopsy in a permanent prostate I-125 implant: a prospective comparative toxicity analysis.

scientific article published on 6 August 2009

Dose perturbation due to catheter materials in high-dose-rate interstitial (192)Ir brachytherapy.

scientific article published on 10 June 2014

Dose to the bladder neck is not correlated with urinary toxicity in patients with prostate cancer treated with HDR brachytherapy boost

scientific article published on 01 September 2020

Dose to tissue medium or water cavities as surrogate for the dose to cell nuclei at brachytherapy photon energies.

scientific article

Dosimetric impact of the variation of the prostate volume and shape between pretreatment planning and treatment procedure

scientific article published on 01 May 2002

Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

scientific article published on 01 January 2012

Dosimetric performance of a multi-point plastic scintillator dosimeter as a tool for real-time source tracking in high dose rate 192 Ir brachytherapy

scientific article published on 22 May 2020

Dosimetric properties of colloidal quantum dot-based systems for scintillation dosimetry

scientific article published on 02 May 2019

Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations

scientific article

EM-enhanced US-based seed detection for prostate brachytherapy

scientific article published on 24 April 2018

Early clinical experience with anatomy-based inverse planning dose optimization for high-dose-rate boost of the prostate

scientific article published on 01 September 2002

Electroseparation of bovine lactoferrin from model and whey solutions

Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kV and 60Co

scientific article published in October 2006

Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms

scientific article published on June 2010

Erratum: Evidence for the statistical and sequential nature of 16O breakup into four alphas

scientific article published on 01 June 1994

Erratum: Medical physics staffing for radiation oncology: a decade of experience in Ontario, Canada.

scientific article

Evaluating the impact of real-time multicriteria optimizers integrated with interactive plan navigation tools for HDR brachytherapy

scientific article published on 23 July 2020

Evaluation of an automatic needle-loading system

scientific article published in April 2004

Evaluation of an electron Monte Carlo dose calculation algorithm for treatment planning.

scientific article published on 8 May 2015

Event-by-event analysis of proton-induced nuclear multifragmentation: determination of the phase transition universality class in a system with extreme finite-size constraints

scientific article published on 26 December 2001

Evidence for the statistical and sequential nature of 16O breakup into four alphas

scientific article published on 01 November 1993

Excitation energies in statistical emission of light charged particles in heavy-ion reactions

scientific article published on 01 June 1995

Exploring (57)Co as a new isotope for brachytherapy applications

scientific article published on 01 May 2012

Extension of the Fermi-Eyges most-likely path in heterogeneous medium with prior knowledge information.

scientific article published on 23 October 2017

Extracting atomic numbers and electron densities from a dual source dual energy CT scanner: experiments and a simulation model

scientific article published on 15 September 2011

Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector.

scientific article

Extraction of depth-dependent perturbation factors for silicon diodes using a plastic scintillation detector

scientific article published in October 2011

Fast GPU-based Monte Carlo simulations for LDR prostate brachytherapy.

scientific article published on 10 June 2015

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

scientific article published on March 2015

Functional avoidance of lung in plan optimization with an aperture-based inverse planning system.

scientific article published on 29 September 2011

High resolution 2D dose measurement device based on a few long scintillating fibers and tomographic reconstruction

scientific article published in August 2012

High-dose-rate brachytherapy boost for prostate cancer treatment: Different combinations of hypofractionated regimens and clinical outcomes

scientific article published on 23 June 2017

Idealized line source configuration for permanent 125I prostate implants

scientific article published on 01 August 2004

Image-Guided High-Dose-Rate (HDR) Boost Localization Using MRI/MR Spectroscopy: A Correlation Study with Biopsy.

scientific article published on 21 September 2016

Image-guided high-dose-rate brachytherapy boost to the dominant intraprostatic lesion using multiparametric magnetic resonance imaging including spectroscopy: Results of a prospective study.

scientific article published on 12 October 2016

Impact of interseed attenuation and tissue composition for permanent prostate implants

scientific article published in March 2006

In-phantom dose verification of prostate IMRT and VMAT deliveries using plastic scintillation detectors

scientific article

Individualized margins in 3D conformal radiotherapy planning for lung cancer: analysis of physiological movements and their dosimetric impacts

scientific article published on 01 March 2008

Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant

scientific article published on 29 July 2010

Intratumoral Injection of Low-Energy Photon-Emitting Gold Nanoparticles: A Microdosimetric Monte Carlo-Based Model

scientific article published on 12 March 2018

Investigation of geometric distortions on magnetic resonance and cone beam computed tomography images used for planning and verification of high-dose rate brachytherapy cervical cancer treatment

scientific article

Investigation of the quinine sulfate dihydrate spectral properties and its effects on Cherenkov dosimetry

scientific article published on 07 August 2019

Isospin diffusion and the nuclear symmetry energy in heavy ion reactions

scientific article published on 10 February 2004

Isospin fractionation in nuclear multifragmentation

scientific article published on 01 July 2000

Laboratory Characterization and Influence of Mineralogy and Grading on the Performance of Treated and Untreated Granular Materials Used as Surface Pavements in Unpaved Road

scholarly article by L. Beaulieu et al published 2010 in Advances in Civil Engineering

Large-scale Retrospective Monte Carlo Dosimetric Study for Permanent Implant Prostate Brachytherapy

scientific article published on 23 November 2016

Layered mass geometry: a novel technique to overlay seeds and applicators onto patient geometry in Geant4 brachytherapy simulations.

scientific article published on 14 September 2012

Liquid to vapor phase transition in excited nuclei

scientific article published on 15 January 2002

MO-D-144-01: Ultrasound Guided RT Intervention & Novel Technologies

scientific article

MO-DE-BRA-04: The CREATE Medical Physics Research Training Network: Training of New Generation Innovators

Measurement accuracy and cerenkov removal for high performance, high spatial resolution scintillation dosimetry

scientific article published in January 2006

Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers

scientific article published in September 2004

Measurements of low-energy (d,n) reactions for BNCT. Boron Neutron Capture Therapy

scientific article published on 01 May 1999

Medical physics staffing for radiation oncology: a decade of experience in Ontario, Canada

scientific article published on 05 January 2012

Modeling a hypothetical 170Tm source for brachytherapy applications

scientific article published in October 2011

Monte Carlo calculation of the dose perturbations in a dual-source HDR/PDR afterloader treatment unit.

scientific article published in July 2016

Monte Carlo dosimetric characterization of a new high dose rate 169 Yb brachytherapy source and independent verification using a multipoint plastic scintillator detector

scientific article published on 19 July 2020

Monte Carlo dosimetry of high dose rate gynecologic interstitial brachytherapy.

scientific article

Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant.

scientific article

Multicenter Evaluation of Biochemical Relapse-Free Survival Outcomes for Intraoperatively Planned Prostate Brachytherapy Using an Automated Delivery System.

scientific article published on 6 June 2017

Multiobjective optimization with a modified simulated annealing algorithm for external beam radiotherapy treatment planning

scientific article published in December 2006

Novel, full 3D scintillation dosimetry using a static plenoptic camera

scientific article published on August 2014

Octree indexing of DICOM images for voxel number reduction and improvement of Monte Carlo simulation computing efficiency

scientific article published in August 2006

On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry.

scientific article published on 08 March 2013

On the sensitivity of α/β prediction to dose calculation methodology in prostate brachytherapy.

scientific article published in February 2014

On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy

scientific article published on June 2013

Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy

scientific article published on 02 April 2019

Optimization of photon beam energy in aperture‐based inverse planning.

scientific article published on 3 September 2009

Patient-specific Monte Carlo-based dose-kernel approach for inverse planning in afterloading brachytherapy

scientific article published on 13 November 2010

Performance and suitability assessment of a real-time 3D electromagnetic needle tracking system for interstitial brachytherapy

scientific article

Performance assessment of a 2D array of plastic scintillation detectors for IMRT quality assurance.

scientific article

Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm

scientific article published in October 2004

Permanent prostate implant using high activity seeds and inverse planning with fast simulated annealing algorithm: A 12-year Canadian experience.

scientific article published on 2 November 2006

Pionic Fusion of Heavy Ions

scientific article published on 01 September 1996

Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators

scientific article published in July 2005

Po-Poster - 20: Octree based compression method of DICOM images for voxel number reduction and faster Monte Carlo simulations

scientific article published on 30 April 2013

Poster - Thurs Eve-02: 3 dimensional ultrasound-guided breast brachytherapy

scientific article

Poster - Thurs Eve-37: Energy and irradiation modality independence of calibration coefficients for water equivalent plastic scintillation detectors in the megavoltage range

scientific article published in July 2008

Poster - Thurs Eve-39: Full 3D dose calculation for total body irradiation: A comparison study between treatment planning systems in homogeneous and heterogeneous conditions

scientific article published on 01 July 2008

Postimplant dosimetry using a Monte Carlo dose calculation engine: a new clinical standard

scientific article published on 30 April 2007

Postoperative irradiation of gynecologic malignancies: improving treatment delivery using aperture-based intensity-modulated radiotherapy.

scientific article

Pre-treatment patient-specific stopping power by combining list-mode proton radiography and x-ray CT.

scientific article published on 28 June 2017

Preclinical dose verification using a 3D printed mouse phantom for radiobiology experiments

scientific article published on 11 September 2019

Prostate postbrachytherapy seed distribution: comparison of high-resolution, contrast-enhanced, T1- and T2-weighted endorectal magnetic resonance imaging versus computed tomography: initial experience: in regard to BLOCH et al. (Int J Radiat Oncol B

scientific article

Prostatic edema in 125I permanent prostate implants: dynamical dosimetry taking volume changes into account

scientific article published in March 2006

Quantifying the effect of seed orientation in postplanning dosimetry of low-dose-rate prostate brachytherapy.

scientific article published in October 2014

Real-time electromagnetic seed drop detection for permanent implants brachytherapy: Technology overview and performance assessment

scientific article

Real-time electromagnetic tracking-based treatment platform for high-dose-rate prostate brachytherapy: Clinical workflows and end-to-end validation.

scientific article published on 30 May 2017

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

scientific article

Reduction of bacterial biofilm formation using marine natural antimicrobial peptides

scientific article published on 27 April 2018

Relationship between isotope half-life and prostatic edema for optimal prostate dose coverage in permanent seed implants

scientific article published in May 2008

Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation.

scientific article published on October 2012

Review of plastic and liquid scintillation dosimetry for photon, electron, and proton therapy

scientific article

Robust shell passivation of CdSe colloidal quantum dots to stabilize radioluminescence emission

Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID.

scientific article published in July 2003

SU-C-201-01: Core/shell and Multishell Colloidal Quantum Dots Nanodosimeters Behaviour Under Repeated MV and KV Irradiations

SU-E-T-265: Reducing Pacemaker Doses with a Lead Sheet: A Multi-Detector Study

scientific article published on 01 June 2012

SU-E-T-509: DICOM Test Case Plans for Model-Based Dose Calculations Methods in Brachytherapy

scientific article published on 11 July 2013

SU-E-T-526: On the Linearity, Stability and Beam Energy Dependence of CdSe Quantum Dots as Scintillating Probes

SU-F-E-17: A Dedicated Teaching and Research Linac as a Stepping Stone to Introduce Medical Physics to Students

scientific article published on 01 June 2016

SU-FF-T-275: Octree Based Compression Method of DICOM Images for Voxel Number Reduction and Faster Monte Carlo Simulations

scientific article published on 29 June 2005

Sci-Fri PM: Planning-04: Dose escalation study using anatomy-based aperture IMRT and SPECT perfusion images for lung cancer

scientific article

Sci-Sat AM(2): Brachy-05: Dosimetry effects of the TG-43 approximations for two iodine seeds in LDR brachytherapy

scientific article published on 01 July 2008

Sci-Sat AM: Brachy - 07: Plastic scintillation detector validation for kV dosimetry

scientific article published on 01 July 2012

Sci-Sat AM: Brachy - 10: Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy.

scientific article published in July 2012

Sci-Thur PM: YIS - 05: Tomographic dosimetry using scintillating fibers and its application to 2D and 3D dosimetry.

scientific article published in July 2012

Sci-Thur PM: YIS - 10: A new optically encoded single-fiber plastic scintillation detector for multi-point radiation dosimetry

scientific article published on 01 July 2012

Sci-Thurs PM: Delivery-12: Correction and calibration of megavoltage cone-beam CT images for the calculation of the dose of the day.

scientific article published on July 2008

Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition.

scientific article published in October 2010

Signals for a transition from surface to bulk emission in thermal multifragmentation

scientific article published on 01 June 2000

Simulation of the precision limits of plastic scintillation detectors using optimal component selection

scientific article

Simulation study on potential accuracy gains from dual energy CT tissue segmentation for low-energy brachytherapy Monte Carlo dose calculations.

scientific article

Simultaneous electroseparation of anionic and cationic peptides: Impact of feed peptide concentration on migration rate, selectivity and relative energy consumption

Simultaneous optimization of beam orientations, wedge filters and field weights for inverse planning with anatomy-based MLC fields

scientific article published in June 2004

Sliding slice: a novel approach for high accuracy and automatic 3D localization of seeds from CT scans

scientific article published in January 2005

Special section: Selected papers from the Fifth International Workshop on Monte Carlo Techniques in Medical Physics

scientific article published on 10 June 2015

Special section: Selected papers from the Fourth International Workshop on Recent Advances in Monte Carlo Techniques for Radiation Therapy.

scientific article published in June 2012

Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.

scientific article

Statistical interpretation of the correlation between intermediate mass fragment multiplicity and transverse energy

scholarly article

Sub-second high dose rate brachytherapy Monte Carlo dose calculations with bGPUMCD.

scientific article published on July 2012

Surface preparation and coupling in plastic scintillator dosimetry.

scientific article published in September 2006

Systematic evaluation of photodetector performance for plastic scintillation dosimetry

scientific article published on 01 November 2015

TU-FG-BRB-04: A New Optimization Method for Pre-Treatment Patient-Specific Stopping-Power by Combining Proton Radiography and X-Ray CT.

scientific article

Technical Note: Identification of an optimal electromagnetic sensor for in vivo electromagnetic-tracked scintillation dosimeter for HDR brachytherapy

scientific article published on 15 April 2019

Technical Note: On EM Reconstruction of a Multi Channel Shielded Applicator for Cervical Cancer Brachytherapy: A Feasibility Study.

scientific article published on 5 February 2018

Technical note: determining regions of interest for CCD camera-based fiber optic luminescence dosimetry by examining signal-to-noise ratio

scientific article published in March 2011

Technical note: removing the stem effect when performing Ir-192 HDR brachytherapy in vivo dosimetry using plastic scintillation detectors: a relevant and necessary step.

scientific article

The association of intraprostatic calcifications and dosimetry parameters with biochemical control after permanent prostate implant

scientific article published on 20 August 2019

The collapsed cone algorithm for (192)Ir dosimetry using phantom-size adaptive multiple-scatter point kernels.

scientific article published on 25 June 2015

The difference of scoring dose to water or tissues in Monte Carlo dose calculations for low energy brachytherapy photon sources

scientific article published in March 2011

The evolution of brachytherapy treatment planning

scientific article published on June 2009

The robustness of dose distributions to displacement and migration of 125I permanent seed implants over a wide range of seed number, activity, and designs

scientific article published in March 2004

The use of tetrahedral mesh geometries in Monte Carlo simulation of applicator based brachytherapy dose distributions

scientific article published on 11 September 2014

Three-dimensional ultrasound system for guided breast brachytherapy

scientific article published on 01 November 2009

Tissue modeling schemes in low energy breast brachytherapy.

scientific article published on 21 October 2011

Tissue segmentation in Monte Carlo treatment planning: a simulation study using dual-energy CT images

scientific article published in January 2008

Toward a real-time in vivo dosimetry system using plastic scintillation detectors

scientific article

Towards real-time 3D ultrasound planning and personalized 3D printing for breast HDR brachytherapy treatment.

scientific article published on 27 February 2015

Use of 3D transabdominal ultrasound imaging for treatment planning in cervical cancer brachytherapy: Comparison to magnetic resonance and computed tomography

scientific article published on 25 April 2017

Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range

scientific article

Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics

scientific article published in March 2004

Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy.

scientific article

Validation of plastic scintillation detectors for applications in low-dose-rate brachytherapy.

scientific article published on 8 May 2017

Validation of the Oncentra Brachy Advanced Collapsed cone Engine for a commercial (192)Ir source using heterogeneous geometries.

scientific article published on 21 September 2015

WE-G-BRB-04: BEST IN PHYSICS (THERAPY) - A Novel Multi-Point Plastic Scintillation Detector for in Vivo Dosimetry and Quality Assurance in Radiation Therapy

scientific article published on 01 June 2012

WE-G-BRB-05: On the Importance of Fluorescence Within the Stem Effect of Scintillation Detectors

scientific article published on 01 June 2012

WE-G-BRB-06: Real-Time Radiation Field Tracking Using Long Scintillating Fibers.

scientific article published in June 2012

Water-dispersable colloidal quantum dots for the detection of ionizing radiation

scientific article

Water-equivalent dosimeter array for small-field external beam radiotherapy.

scientific article published in May 2007

[Clinical outcome of intermediate risk prostate cancer treated with iodine 125 monotherapy: The Hotel-Dieu of Quebec experience]

scientific article published on 24 April 2010

[The impact of 3D image guided prostate brachytherapy on therapeutic ratio: the Quebec University Hospital experience]

scientific article published on 09 November 2007