Search filters

List of works by Dieter H. Pahr

A calibration methodology of QCT BMD for human vertebral body with registered micro-CT images

scientific article published in May 2011

A comparison of enhanced continuum FE with micro FE models of human vertebral bodies.

scientific article published on 19 January 2009

A nonlinear finite element model validation study based on a novel experimental technique for inducing anterior wedge-shape fractures in human vertebral bodies in vitro.

scientific article published on 11 May 2010

A patient-specific finite element methodology to predict damage accumulation in vertebral bodies under axial compression, sagittal flexion and combined loads.

scientific article

A round-robin finite element analysis of human femur mechanics between seven participating laboratories with experimental validation

scientific article published on 13 May 2019

An experimentally validated finite element method for augmented vertebral bodies

scientific article published on 17 October 2012

Assessment of transverse isotropy in clinical-level CT images of trabecular bone using the gradient structure tensor.

scientific article

Biomechanical Testing of Distal Radius Fracture Treatments: Boundary Conditions Significantly Affect the Outcome of In Vitro Experiments.

scientific article published on 3 November 2015

Cement distribution, volume, and compliance in vertebroplasty: some answers from an anatomy-based nonlinear finite element study.

scientific article published in July 2008

Clinical versus pre-clinical FE models for vertebral body strength predictions.

scientific article published on 20 December 2012

Comparison of mixed and kinematic uniform boundary conditions in homogenized elasticity of femoral trabecular bone using microfinite element analyses

scientific article published on January 2015

Comparison of proximal femur and vertebral body strength improvements in the FREEDOM trial using an alternative finite element methodology.

scientific article

Computational and experimental methodology for site-matched investigations of the influence of mineral mass fraction and collagen orientation on the axial indentation modulus of lamellar bone

scientific article

DXA predictions of human femoral mechanical properties depend on the load configuration.

scientific article published on 16 May 2013

Distributed High-Performance Parallel Mesh Generation with ViennaMesh

Effect of boundary conditions on yield properties of human femoral trabecular bone.

scientific article published on 30 October 2015

Efficient materially nonlinear [Formula: see text]FE solver for simulations of trabecular bone failure

scientific article published on 20 November 2019

Elastic anisotropy of bone lamellae as a function of fibril orientation pattern

scientific article published on 27 April 2010

Experimental validation of DXA-based finite element models for prediction of femoral strength.

scientific article published on 10 June 2016

Experimental validation of a nonlinear μFE model based on cohesive-frictional plasticity for trabecular bone

scientific article

Fabric-based Tsai-Wu yield criteria for vertebral trabecular bone in stress and strain space

scientific article published on 20 July 2012

Fast estimation of Colles' fracture load of the distal section of the radius by homogenized finite element analysis based on HR-pQCT.

scientific article published on 6 January 2017

Finite Element-Based Mechanical Assessment of Bone Quality on the Basis of In Vivo Images

scientific article

Finite element analysis for prediction of bone strength

scientific article published on 07 August 2013

From high-resolution CT data to finite element models: development of an integrated modular framework

scientific article

HR-pQCT based FE analysis of the most distal radius section provides an improved prediction of Colles' fracture load in vitro

scientific article published on August 6, 2010

HR-pQCT-based homogenised finite element models provide quantitative predictions of experimental vertebral body stiffness and strength with the same accuracy as μFE models.

scientific article published on 24 May 2011

Human evolution. Human-like hand use in Australopithecus africanus

scientific article published in January 2015

Human evolution. Response to Comment on "Human-like hand use in Australopithecus africanus".

scientific article published on June 2015

Ibandronate increases sclerostin levels and bone strength in male patients with idiopathic osteoporosis.

scientific article

Identification of a crushable foam material model and application to strength and damage prediction of human femur and vertebral body.

scientific article

Identification of elastic properties of human patellae using micro-finite element analysis.

scientific article published on 30 July 2016

Improvements in Vertebral Body Strength Under Teriparatide Treatment Assessed In Vivo by Finite Element Analysis: Results From the EUROFORS Study

article

Influence of boundary conditions on computed apparent elastic properties of cancellous bone.

scientific article

Measurement of structural anisotropy in femoral trabecular bone using clinical-resolution CT images.

scientific article published on 9 August 2013

Micro-finite element (μFE) modeling of the siamang (Symphalangus syndactylus) third proximal phalanx: the functional role of curvature and the flexor sheath ridge

scientific article published on 2 February 2014

Mineral heterogeneity has a minor influence on the apparent elastic properties of human cancellous bone: a SRμCT-based finite element study

scientific article published on 23 January 2012

Modeling and experimental validation of trabecular bone damage, softening and densification under large compressive strains

scientific article published on 20 June 2012

On Analyzing Quality of Data Influences on Performance of Finite Elements Driven Computational Simulations

scholarly article by Michael Reiter et al published 2012 in Lecture Notes in Computer Science

Only minor differences in renal osteodystrophy features between wild-type and sclerostin knockout mice with chronic kidney disease.

scientific article

Orthotropic HR-pQCT-based FE models improve strength predictions for stance but not for side-way fall loading compared to isotropic QCT-based FE models of human femurs.

scientific article published on 24 January 2014

Predicting Trabecular Bone Stiffness from Clinical Cone-Beam CT and HR-pQCT Data; an In Vitro Study Using Finite Element Analysis

scientific article

Prediction of apparent trabecular bone stiffness through fourth-order fabric tensors

scientific article published on 4 September 2015

Principal stiffness orientation and degree of anisotropy of human osteons based on nanoindentation in three distinct planes.

scientific article

QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA

article

Relationship between ultrasonic parameters and apparent trabecular bone elastic modulus: a numerical approach.

scientific article published on 30 July 2009

Rotational stability in screw-fixed scaphoid fractures compared to plate-fixed scaphoid fractures

scientific article

Synchrotron X-ray phase nano-tomography-based analysis of the lacunar-canalicular network morphology and its relation to the strains experienced by osteocytes in situ as predicted by case-specific finite element analysis.

scientific article published on 11 July 2014

TBS reflects trabecular microarchitecture in premenopausal women and men with idiopathic osteoporosis and low-traumatic fractures

scientific article published on 16 June 2015

The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty.

scientific article published on 15 December 2011

The effect of the extensor mechanism on maximum isometric fingertip forces: A numerical study on the index finger.

scientific article

The effects of bone and pore volume fraction on the mechanical properties of PMMA/bone biopsies extracted from augmented vertebrae

scientific article published on 27 August 2011

The influence of bone density and anisotropy in finite element models of distal radius fracture osteosynthesis: Evaluations and comparison to experiments.

scientific article published on 19 October 2015

The influence of distal screw length on the primary stability of volar plate osteosynthesis--a biomechanical study

scientific article published on 8 September 2015

The insufficiencies of risk analysis of impending pathological fractures in patients with femoral metastases: A literature review.

scientific article

The mechanical behavior of PMMA/bone specimens extracted from augmented vertebrae: a numerical study of interface properties, PMMA shrinkage and trabecular bone damage

scientific article published on 02 March 2012

The role of cortical shell and trabecular fabric in finite element analysis of the human vertebral body.

scientific article published on November 2009

Tissue properties of the human vertebral body sub-structures evaluated by means of microindentation.

scientific article published on 9 May 2013

Trabecular architecture in the thumb of Pan and Homo: implications for investigating hand use, loading, and hand preference in the fossil record

scientific article published on 8 August 2016

Trabecular bone patterning in the hominoid distal femur.

scientific article published on 5 July 2018

Trabecular bone structure correlates with hand posture and use in hominoids

scientific article (publication date: 2013)

Validation of a voxel-based FE method for prediction of the uniaxial apparent modulus of human trabecular bone using macroscopic mechanical tests and nanoindentation

scientific article published on 18 June 2007

Validation of an HR-pQCT-based homogenized finite element approach using mechanical testing of ultra-distal radius sections.

scientific article published on 5 August 2010

Validation of an anatomy specific finite element model of Colles’ fracture

article