Search filters

List of works by Enrique Berjano

A clinically oriented computer model for radiofrequency ablation of hepatic tissue with internally cooled wet electrode

scientific article published on 08 October 2018

A cooled intraesophageal balloon to prevent thermal injury during endocardial surgical radiofrequency ablation of the left atrium: a finite element study

scientific article published on 27 September 2005

A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom

scientific article published on 16 January 2008

A new method of providing pulsatile flow in a centrifugal pump: assessment of pulsatility using a mock circulatory system

scientific article published on 16 April 2008

A new single-instrument technique for parenchyma division and hemostasis in liver resection: a clinical feasibility study

scientific article published on December 2010

A radiofrequency-assisted device for bloodless rapid transection of the liver: a comparative study in a pig liver model

scientific article published on 5 July 2007

Analytical thermal-optic model for laser heating of biological tissue using the hyperbolic heat transfer equation

scientific article

Analytical validation of COMSOL Multiphysics for theoretical models of Radiofrequency ablation including the Hyperbolic Bioheat transfer equation

scientific article published in January 2010

Applicator for RF thermokeratoplasty: feasibility study using theoretical modeling and ex vivo experiments

scientific article published on 22 December 2011

Assessment of hyperbolic heat transfer equation in theoretical modeling for radiofrequency heating techniques

scientific article published on 10 April 2008

Atrial ablation and esophageal injury: comments on an experimental study

scientific article published on 01 July 2006

Black-box modeling to estimate tissue temperature during radiofrequency catheter cardiac ablation: Feasibility study on an agar phantom model.

scientific article

CT mapping of saline distribution after infusion of saline into the liver in an ex vivo animal model. How much tissue is actually infused in an image-guided procedure?

scientific article

Can electroporation previous to radiofrequency hepatic ablation enlarge thermal lesion size? A feasibility study based on theoretical modelling and in vivo experiments.

scientific article published on 10 April 2013

Comments on Esophageal luminal temperature measurement during radiofrequency ablation of left atrium

scientific article published on 11 November 2008

Computer Modeling for Radiofrequency Bipolar Ablation Inside Ducts and Vessels: Relation Between Pullback Speed and Impedance Progress

scientific article published on 08 March 2020

Computer modeling of electrical and thermal performance during bipolar pulsed radiofrequency for pain relief.

scientific article published on July 2014

Could it be advantageous to tune the temperature controller during radiofrequency ablation? A feasibility study using theoretical models

scientific article published on 01 January 2011

Could the heat sink effect of blood flow inside large vessels protect the vessel wall from thermal damage during RF-assisted surgical resection?

scientific article published on 01 August 2014

Development of a catheter-based technique for endoluminal radiofrequency sealing of pancreatic duct

scientific article published on 01 January 2019

Differences in applied electrical power between full thorax models and limited-domain models for RF cardiac ablation

scientific article published on 01 January 2020

Distant infusion of saline may enlarge coagulation volume during radiofrequency ablation of liver tissue using cool-tip electrodes without impairing predictability

scientific article published in June 2011

Effect of electrode thermal conductivity in cardiac radiofrequency catheter ablation: a computational modeling study

scientific article published in March 2009

Effect of the thermal wave in radiofrequency ablation modeling: an analytical study

scientific article published on 19 February 2008

Effect of the trabecular bone microstructure on measuring its thermal conductivity: A computer modeling-based study

scientific article published on 19 August 2018

Electrical-thermal performance of a cooled RF applicator for hepatic ablation with additional distant infusion of hypertonic saline: in vivo study and preliminary computer modeling

scientific article published on 14 September 2012

Esophageal temperature during radiofrequency-catheter ablation of left atrium: a three-dimensional computer modeling study

scientific article published on 01 April 2006

Esophageal temperature monitoring during radiofrequency catheter ablation: experimental study based on an agar phantom model

scientific article published on 5 April 2007

Esophagus histological analysis after hyperthermia-induced injury: implications for cardiac ablation

scientific article published in March 2009

Evolving technology in bipolar perfused radiofrequency ablation: assessment of efficacy, predictability and safety in a pig liver model

scientific article published on 16 March 2006

Experimental and theoretical study of an internally cooled bipolar electrode for RF coagulation of biological tissues.

scientific article

Feasibility study of an internally cooled bipolar applicator for RF coagulation of hepatic tissue: experimental and computational study

scientific article published on 14 September 2012

Gold-tip electrodes--a new 'deep lesion' technology for catheter ablation? In vitro comparison of gold alloy versus platinum-iridium tip electrode ablation catheter

scientific article published in December 2005

How large is the periablational zone after radiofrequency and microwave ablation? Computer-based comparative study of two currently used clinical devices

scientific article published on 01 January 2020

Impedance measurement to assess epicardial fat prior to RF intraoperative cardiac ablation: a feasibility study using a computer model

scientific article published on 15 October 2010

Improved perfusion system for bipolar radiofrequency ablation of liver: preliminary findings from a computer modeling study.

scientific article published on September 2006

In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump

scientific article published on 18 January 2010

Influence of approach on outcome in radiofrequency ablation of liver tumors.

scientific article published on 08 May 2008

Injury in organs after cardiopulmonary bypass: a comparative experimental morphological study between a centrifugal and a new pulsatile pump

scientific article published on 01 August 2004

Intramural radiofrequency ablation: effects of electrode temperature and length

scientific article published in January 2005

Laparoscopic blood-saving liver resection using a new radiofrequency-assisted device: preliminary report of an in vivo study with pig liver

scientific article published on 6 March 2008

Laparoscopic distal pancreatectomy: feasibility study of radiofrequency-assisted transection in a porcine model

scientific article published on 30 January 2012

Long electrodes for radio frequency ablation: comparative study of surface versus intramural application.

scientific article published in December 2003

Lumped Element Electrical Model based on Three Resistors for Electrical Impedance in Radiofrequency Cardiac Ablation: Estimations from Analytical Calculations and Clinical Data.

scientific article

Mathematical modeling of epicardial RF ablation of atrial tissue with overlying epicardial fat.

scientific article published on 4 February 2010

Mathematical models based on transfer functions to estimate tissue temperature during RF cardiac ablation in real time.

scientific article published on 8 March 2012

Modeling for radio-frequency conductive keratoplasty: implications for the maximum temperature reached in the cornea.

scientific article

Platelet dysfunction in cardiopulmonary bypass: an experimental comparative study between a centrifugal and a new pulsatile pump

scientific article published on 01 December 2003

Pulse wave velocity and digital volume pulse as indirect estimators of blood pressure: pilot study on healthy volunteers.

scientific article

RF tumor ablation with internally cooled electrodes and saline infusion: what is the optimal location of the saline infusion?

scientific article published on 16 July 2007

Radio-frequency heating of the cornea: theoretical model and in vitro experiments

scientific article published on 01 March 2002

Radiofrequency hepatic ablation with internally cooled electrodes and hybrid applicators with distant saline infusion using an in vivo porcine model

scientific article published on 26 November 2007

Radiofrequency is a secure and effective method for pancreatic transection in laparoscopic distal pancreatectomy: results of a randomized, controlled trial in an experimental model.

scientific article published on 13 April 2013

Radiofrequency pancreatic ablation and section of the main pancreatic duct does not lead to necrotizing pancreatitis.

scientific article published in August 2014

Relationship between roll-off occurrence and spatial distribution of dehydrated tissue during RF ablation with cooled electrodes

scientific article published on 01 January 2012

Reliability assessment of a cooled intraesophageal balloon to prevent thermal injury during RF cardiac ablation: an agar phantom study

scientific article published on 4 June 2008

Research and development of a new RF-assisted device for bloodless rapid transection of the liver: computational modeling and in vivo experiments

scientific article published on 18 March 2009

Review of the mathematical functions used to model the temperature dependence of electrical and thermal conductivities of biological tissue in radiofrequency ablation.

scientific article published on 10 July 2013

Ring electrode for radio-frequency heating of the cornea: modelling and in vitro experiments

scientific article published in November 2003

Sensitivity of rheoencephalographic measurements to spatial brain electrical conductivity

scientific article published in January 2006

Single instrument for hemostatic control in laparoscopic partial nephrectomy in a porcine model without renal vascular clamping

scientific article published on 19 May 2011

Small ablation zones created previous to saline infusion result in enlargement of the coagulated area during perfusion RF ablation: an ex vivo experimental study

scientific article

Theoretical and experimental study on RF tumor ablation with internally cooled electrodes: when does the roll-off occur?

scientific article published on 01 January 2011

Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future.

scientific article

Theoretical modeling of RF ablation with internally cooled electrodes: comparative study of different thermal boundary conditions at the electrode-tissue interface

scientific article published in July 2009

Thermal impact of balloon occlusion of the coronary sinus during mitral isthmus radiofrequency ablation: an in-silico study

scientific article published on 01 January 2019

Thermal latency adds to lesion depth after application of high-power short-duration radiofrequency energy: Results of a computer-modeling study

scientific article published on 8 October 2017

Thermal modeling for pulsed radiofrequency ablation: analytical study based on hyperbolic heat conduction

scientific article published in April 2009

Thermal-electrical modeling for epicardial atrial radiofrequency ablation

scientific article published on 01 August 2004

What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysis

scientific article published on 28 July 2005

[Sutureless hepatic transection using a new radiofrequency assisted device. Theoretical model, experimental study and clinic trial]

scientific article published on 02 February 2011