Search filters

List of works by Dennis R. Schaart

A 32 mm  ×  32 mm  ×  22 mm monolithic LYSO:Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI.

scientific article published on 10 June 2016

A comparison of MCNP4C electron transport with ITS 3.0 and experiment at incident energies between 100 keV and 20 MeV: influence of voxel size, substeps and energy indexing algorithm

scientific article published in May 2002

A comparison of intravascular source designs based on the beta particle emitter 114mIn/114In. Line source versus stepping source.

scientific article

A novel, SiPM-array-based, monolithic scintillator detector for PET.

scientific article published on 15 May 2009

A practical method for depth of interaction determination in monolithic scintillator PET detectors.

scientific article published on 21 June 2011

A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications

scientific article published on June 2014

Adaptive liver stereotactic body radiation therapy: automated daily plan reoptimization prevents dose delivery degradation caused by anatomy deformations

scientific article

An enhanced high-resolution EMCCD-based gamma camera using SiPM side detection

scientific article published on 28 October 2010

BGO as a hybrid scintillator / Cherenkov radiator for cost-effective time-of-flight PET.

scientific article published on 30 March 2017

Comparative Characterization Study of a LaBr3(Ce) Scintillation Crystal in Two Surface Wrapping Scenarios: Absorptive and Reflective

scientific article published on 7 December 2015

Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeV.

scientific article published on 14 January 2011

Correlations between the shifts in prompt gamma emission profiles and the changes in daily target coverage during simulated pencil beam scanning proton therapy

scientific article published on 10 April 2019

Dose calculation formalisms and consensus dosimetry parameters for intravascular brachytherapy dosimetry: recommendations of the AAPM Therapy Physics Committee Task Group No. 149

scientific article published on 01 November 2007

Factors influencing the accuracy of beam range estimation in proton therapy using prompt gamma emission.

scientific article published on 22 July 2014

Fast automated multi-criteria planning for HDR brachytherapy explored for prostate cancer

scientific article published on 10 October 2019

First characterization of a digital SiPM based time-of-flight PET detector with 1 mm spatial resolution

scientific article

First in situ TOF-PET study using digital photon counters for proton range verification.

scientific article

First performance tests of a digital photon counter (DPC) array coupled to a CsI(Tl) crystal matrix for potential use in SPECT.

scientific article published on 17 April 2014

GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy

scientific article published on 20 January 2011

GATE: a simulation toolkit for PET and SPECT.

scientific article

Geometric optimization of an ultralow-dose high-resolution pediatric PET scanner based on monolithic scintillators with dSiPM readout

scientific article published on December 2015

Improved EMCCD gamma camera performance by SiPM pre-localization

scientific article published on 02 November 2012

LaBr(3):Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time.

scientific article published on 19 March 2010

Limits on the spatial resolution of monolithic scintillators read out by APD arrays

scientific article published on 21 September 2012

Model of the point spread function of monolithic scintillator PET detectors for perpendicular incidence

scientific article published in April 2010

Modelling of a 188W/188Re beta line source for coronary brachytherapy by means of EGS4 Monte Carlo simulations

scientific article published on 01 May 2000

Monolithic LaBr₃:Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography.

scientific article

Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction

scientific article published on 05 March 2009

Monte Carlo calculations of positron emitter yields in proton radiotherapy.

scientific article published on 7 March 2012

On the applicability of the AAPM TG-60/TG-43 dose calculation formalism to intravascular line sources: proposal for an adapted formalism

scientific article published on 01 April 2001

Optical simulation of monolithic scintillator detectors using GATE/GEANT4.

scientific article published on 24 February 2010

Optimization of an ultralow-dose high-resolution pediatric PET scanner design based on monolithic scintillators with dual-sided digital SiPM readout: a simulation study.

scientific article published on 25 September 2017

Recommendations on detectors and quality control procedures for brachytherapy beta sources

scientific article published on 2 February 2006

Reconstructing 3D proton dose distribution using ionoacoustics

scientific article published on 15 November 2019

Scintillation properties of Ca co-doped L(Y)SO:Ce between 193 K and 373 K for TOF-PET/MRI.

scientific article published on July 2014

Sub-200 ps CRT in monolithic scintillator PET detectors using digital SiPM arrays and maximum likelihood interaction time estimation

scientific article

Sub-3 mm, near-200 ps TOF/DOI-PET imaging with monolithic scintillator detectors in a 70 cm diameter tomographic setup

scientific article published on 27 July 2018

The lower bound on the timing resolution of scintillation detectors

scientific article published on 13 March 2012

The price of robustness; impact of worst-case optimization on organ-at-risk dose and complication probability in intensity-modulated proton therapy for oropharyngeal cancer patients

scientific article published on 10 May 2016

The radial depth-dose distribution of a 188W/188Re beta line source measured with novel, ultra-thin TLDs in a PMMA phantom: comparison with Monte Carlo simulations

scientific article published on 01 October 2002

The scaling method applied to beta particle line sources with a finite diameter

scientific article published in November 2002

The statistical distribution of the number of counted scintillation photons in digital silicon photomultipliers: model and validation

scientific article published on 13 July 2012

Time estimation with multichannel digital silicon photomultipliers

scientific article published on 5 March 2015

Time-based position estimation in monolithic scintillator detectors.

scientific article published on 2 July 2015

Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification: a simulation study

scientific article published on 21 September 2012

Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters.

scientific article published on 28 July 2015

Towards monolithic scintillator based TOF-PET systems: practical methods for detector calibration and operation

scientific article published on 10 June 2016

Variable circular collimator in robotic radiosurgery: a time-efficient alternative to a mini-multileaf collimator?

scientific article

Variation in interpretation of the AAPM TG-43 geometry factor leads to unclearness in brachytherapy dosimetry

scientific article published on 01 September 2001