Advanced search

Authors whose works are in public domain in at least one jurisdiction

List of works by Diethard Schmidt

Automated saline-enhanced radiofrequency thermal ablation: initial results in ex vivo bovine livers

scientific article published on 01 January 2003

Bipolar radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver: prediction of coagulation volume from applied energy

scientific article published in January 2007

In vivo efficiency of four commercial monopolar radiofrequency ablation systems: a comparative experimental study in pig liver

scientific article

Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver

scientific article published on 01 December 2009

Influence of NaCl concentrations on coagulation, temperature, and electrical conductivity using a perfusion radiofrequency ablation system: an ex vivo experimental study

scientific article published in January 2007

MR-guided radiofrequency ablation in a 0.2-T open MR system: technical success and technique effectiveness in 100 liver tumors

scientific article published on 01 October 2007

MR-guided radiofrequency ablation of hepatocellular carcinoma: long-term effectiveness

scientific article published on 06 May 2011

MR-guided radiofrequency ablation: do magnetic fields influence extent of coagulation in ex vivo bovine livers?

scientific article published in December 2006

Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study

scientific article published in April 2004

Magnetic resonance-guided percutaneous radiofrequency ablation of renal cell carcinomas: a pilot clinical study

scientific article published on 01 September 2005

Multipolar radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver: correlation between volume of coagulation and amount of applied energy

scientific article published on 27 November 2010

Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling.

scientific article published on 19 January 2006

Percutaneous MR-guided radiofrequency ablation of recurrent sacrococcygeal chordomas

scientific article published in August 2006

Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time

scientific article published on September 30, 2011

Prolonged Antibiotic Prophylaxis in Patients with Bilioenteric Anastomosis Undergoing Percutaneous Radiofrequency Ablation

scientific article published on February 22, 2012

Radiofrequency ablation: in vivo comparison of four commercially available devices in pig livers

scientific article published in August 2004

Radiofrequency ablation: the percutaneous approach

scientific article published on January 2006

Sustained growth of the ex vivo ablation zones' critical short axis using gas-cooled radiofrequency applicators

scientific article published on 27 July 2010

Thermal damage of the genitofemoral nerve due to radiofrequency ablation of renal cell carcinoma: a potentially avoidable complication

scientific article published on 01 December 2005